419 research outputs found

    Analysis of Nuclear DNA Content and Karyotype of Phaseolus vulgaris L.

    Get PDF
    The common bean (Phaseolus vulgaris L.), whose annual production is 26 million tons worldwide, is one of the main sources of protein and is known as one of the most important food sources. In this study, the karyotype variations and the genome size of four common bean genotypes in Turkey were investigated to determine whether the geographic variables in these regions affected the genome size and the karyotype parameters. In addition, it is known that as that the cytological and chromosomal parameters change under the influence of the climatic conditions of each region, appropriate and stable cytological methods for each plant facilitate and enable the determination of the chromosomal structure and the identification of specific chromosomes in the genotypes of the relevant region. Correct and valuable information such as this enables breeders and researchers to determine the correct shape and actual size of chromosomes. The genome size of the genotypes was measured with a flow cytometer, and chromosome analyses were performed with the squash method. For each genotype, the karyotype parameters, such as the number of somatic chromosomes, the Mean Total Chromosome Length (MTCL), the Mean Centromere Index (MCI), and the Mean Arm Ratio (MAR), were measured. The results showed that the highest and the lowest amounts of DNA per nucleus (3.28 pg and 1.49 pg) were observed in the Bitlis and Elaziğ genotypes. In addition, all genotype chromosome numbers were counted to be 2n = 2x = 22. The Mean Total Chromosome Length varied from 15.65 µm in Elaziğ to 34.24 µm in the Bitlis genotype. The Mean Chromosome Length ranged between 1.42 µm and 3.11 µm in the Elaziğ and Bitlis genotypes. The Hakkari and Van genotypes consist of eleven metacentric chromosomes, while the Bitlis and Elaziğ genotypes consist of ten metacentric chromosomes and one sub-metacentric chromosome. However, the Mean Centromere Index and Arm Ratio differed considerably among the genotypes. The highest (46.88) and the lowest (43.18) values of the Mean Centromere Index were observed in the Hakkari and Elaziğ genotypes, respectively. On the other hand, the lowest (1.15) and the highest (1.36) values of the Mean Arm Ratio were obtained in the Bitlis and Elaziğ genotypes, respectively. Eventually, intraspecies variations in genome size and chromosomal parameters were observed, and it was determined that the changes in nuclear DNA content and different chromosomal parameters among the four Phaseolus genotypes from four different regions of Turkey indicate the effect of climate change in the regions on these parameters. Such information in these areas can be used as useful information for the improvement of this plant and breeding programs

    PW01-016 – Are different disease subtypes present in FMF

    Full text link

    Analysis of Nuclear DNA Content and Karyotype of Phaseolus vulgaris L.

    Get PDF
    The common bean (Phaseolus vulgaris L.), whose annual production is 26 million tons worldwide, is one of the main sources of protein and is known as one of the most important food sources. In this study, the karyotype variations and the genome size of four common bean genotypes in Turkey were investigated to determine whether the geographic variables in these regions affected the genome size and the karyotype parameters. In addition, it is known that as that the cytological and chromosomal parameters change under the influence of the climatic conditions of each region, appropriate and stable cytological methods for each plant facilitate and enable the determination of the chromosomal structure and the identification of specific chromosomes in the genotypes of the relevant region. Correct and valuable information such as this enables breeders and researchers to determine the correct shape and actual size of chromosomes. The genome size of the genotypes was measured with a flow cytometer, and chromosome analyses were performed with the squash method. For each genotype, the karyotype parameters, such as the number of somatic chromosomes, the Mean Total Chromosome Length (MTCL), the Mean Centromere Index (MCI), and the Mean Arm Ratio (MAR), were measured. The results showed that the highest and the lowest amounts of DNA per nucleus (3.28 pg and 1.49 pg) were observed in the Bitlis and Elaziğ genotypes. In addition, all genotype chromosome numbers were counted to be 2n = 2x = 22. The Mean Total Chromosome Length varied from 15.65 µm in Elaziğ to 34.24 µm in the Bitlis genotype. The Mean Chromosome Length ranged between 1.42 µm and 3.11 µm in the Elaziğ and Bitlis genotypes. The Hakkari and Van genotypes consist of eleven metacentric chromosomes, while the Bitlis and Elaziğ genotypes consist of ten metacentric chromosomes and one sub-metacentric chromosome. However, the Mean Centromere Index and Arm Ratio differed considerably among the genotypes. The highest (46.88) and the lowest (43.18) values of the Mean Centromere Index were observed in the Hakkari and Elaziğ genotypes, respectively. On the other hand, the lowest (1.15) and the highest (1.36) values of the Mean Arm Ratio were obtained in the Bitlis and Elaziğ genotypes, respectively. Eventually, intraspecies variations in genome size and chromosomal parameters were observed, and it was determined that the changes in nuclear DNA content and different chromosomal parameters among the four Phaseolus genotypes from four different regions of Turkey indicate the effect of climate change in the regions on these parameters. Such information in these areas can be used as useful information for the improvement of this plant and breeding programs

    Assessment of the roughness factor effect and the intrinsic catalytic activity for hydrogen evolution reaction on Ni-based electrodeposits

    Full text link
    The hydrogen evolution reaction (HER) was studied in 30 wt.% KOH solution at temperatures ranging between 30 and 80 °C on three type of electrodes: (i) rough pure Ni electrodeposits, obtained by applying a large current density; (ii) smooth NiCo electrodeposits; (iii) smooth commercial Ni electrodes. By using steady-state polarization curves and electrochemical impedance spectroscopy (EIS) the surface roughness factor and the intrinsic activities of the catalytic layers were determined. These techniques also permitted us to determine the mechanism and kinetics of the HER on the investigated catalysts. Different AC models were tested and the appropriate one was selected. The overall experimental data indicated that the rough/porous Ni electrode yields the highest electrocatalytic activity in the HER. Nevertheless, when the effect of the surface roughness was taken into consideration, it was demonstrated that alloying Ni with Co results in an increased electrocatalytic activity in the HER when comparing to pure Ni. This is due to an improved intrinsic activity of the material, which was explained on the basis of the synergism among the catalytic properties of Ni (low hydrogen overpotential) and of Co (high hydrogen adsorption).Isaac Herraiz-Cardona is grateful to the Ministerio de Ciencia e Innovacion (Spain) for a postgraduate grant (Ref. AP2007-03737). This work was supported by Generalitat Valenciana (Project PROMETEO/2010/023)Herraiz Cardona, I.; Ortega Navarro, EM.; Garcia-Anton, J.; Pérez-Herranz, V. (2011). Assessment of the roughness factor effect and the intrinsic catalytic activity for hydrogen evolution reaction on Ni-based electrodeposits. International Journal of Hydrogen Energy. 36(16):9428-9438. https://doi.org/10.1016/j.ijhydene.2011.05.047S94289438361

    Signal yields, energy resolution, and recombination fluctuations in liquid xenon

    Get PDF
    This work presents an analysis of monoenergetic electronic recoil peaks in the dark-matter-search and calibration data from the first underground science run of the Large Underground Xenon (LUX) detector. Liquid xenon charge and light yields for electronic recoil energies between 5.2 and 661.7 keV are measured, as well as the energy resolution for the LUX detector at those same energies. Additionally, there is an interpretation of existing measurements and descriptions of electron-ion recombination fluctuations in liquid xenon as limiting cases of a more general liquid xenon re- combination fluctuation model. Measurements of the standard deviation of these fluctuations at monoenergetic electronic recoil peaks exhibit a linear dependence on the number of ions for energy deposits up to 661.7 keV, consistent with previous LUX measurements between 2-16 keV with 3^3H. We highlight similarities in liquid xenon recombination for electronic and nuclear recoils with a comparison of recombination fluctuations measured with low-energy calibration data.Comment: 11 pages, 12 figures, 3 table

    Identification of Radiopure Titanium for the LZ Dark Matter Experiment and Future Rare Event Searches

    Full text link
    The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. The large mass and proximity of the cryostat to the active detector volume demand the use of material with extremely low intrinsic radioactivity. We report on the radioassay campaign conducted to identify suitable metals, the determination of factors limiting radiopure production, and the selection of titanium for construction of the LZ cryostat and other detector components. This titanium has been measured with activities of 238^{238}Ue_{e}~<<1.6~mBq/kg, 238^{238}Ul_{l}~<<0.09~mBq/kg, 232^{232}The_{e}~=0.28±0.03=0.28\pm 0.03~mBq/kg, 232^{232}Thl_{l}~=0.25±0.02=0.25\pm 0.02~mBq/kg, 40^{40}K~<<0.54~mBq/kg, and 60^{60}Co~<<0.02~mBq/kg (68\% CL). Such low intrinsic activities, which are some of the lowest ever reported for titanium, enable its use for future dark matter and other rare event searches. Monte Carlo simulations have been performed to assess the expected background contribution from the LZ cryostat with this radioactivity. In 1,000 days of WIMP search exposure of a 5.6-tonne fiducial mass, the cryostat will contribute only a mean background of 0.160±0.0010.160\pm0.001(stat)±0.030\pm0.030(sys) counts.Comment: 13 pages, 3 figures, accepted for publication in Astroparticle Physic
    corecore